Total Concrete 0.00 m³
Total Steel 0.00 kg
Avg. Density 0.00 kg/m³
Main 0.00 kg
Links 0.00 kg
Side 0.00 kg

No Beams Added Yet

Drag and drop .C01 files here, or click the "Add .C01 Files" button to get started.

Beam Mark Quantity Density (kg/m³) Actions Concrete (m³) Main Bar (kg) Links (kg) Side Bar (kg) Total Steel (kg)

Beam Graphics Module

Select a beam from the dashboard to view its steel arrangement.

Default Grade: If a beam's concrete grade (Fck) is not found in the list below, the values from the grade marked as Default will be used.

Configuration (Grade and Hook Length)

Loading configuration...

Density KPI Settings

Set the target range for steel density (kg/m³). Values outside this range will be highlighted in red.

DXF Export Scale Settings

Configure the vertical exaggeration scale for exported DXF beam profiles.

Default is 3.0 (i.e. 1 : 3 horizontal-to-vertical exaggeration). Set to 1.0 for true 1:1 scale.
Distance from the beam outline to the bar centreline, measured into the beam. Default is 35 mm; set to 0 to draw bars directly on the face.

Sharp Drop Treatment

A sharp drop is a near-vertical step in the beam outline. Drops that strictly exceed the splitting tolerance interrupt the bar (top bars: anchored hook on high side, straight tension anchorage on low side; bottom bars: straight tension anchorage on high side, anchored hook bending up on low side); steps smaller than or equal to this tolerance take no action. A slope that changes from falling to flat/rising or flat to rising (top bars) or from rising to flat/falling or flat to falling (bottom bars) is split at the kink, with each piece lapping past the kink by the tension anchorage (minimum 500 mm) along its own gradient.

Steps smaller than this are ignored with no action. Default is 50 mm.
A step counts as "sharp" only if its two face points are within this horizontal distance. Longer changes are treated as slopes. Default is 50 mm.
Drops strictly greater than this value split and anchor the bar over the step; drops less than or equal to this take no action. Default is 75 mm.

Column Faces

At every support a column is assumed and its faces are drawn as yellow lines on the LINK layer. Shear-link dimensions stop at these faces.

Half-width of the assumed column at each support. Default is 75 mm each side (150 mm total).

Shear Link Dimensions

Controls the placement and formatting of shear-link dimension lines below the beam soffit.

Distance from the soffit to the link dimension line. Default is 450 mm.
Added to the offset for each additional bottom reinforcement layer. Default is 225 mm per layer.
When checked, the link mark (e.g. T10-300) is above the line and the measured span length is below the line. When unchecked, only the link mark is shown above the line.

Dimensions & Leaders

Overall annotation sizing used by all dimensions and reinforcement leaders in the exported DXF.

Height of rebar text annotations (e.g. 2T16). Default is 250 mm.
Overall scale factor applied to dimensions and leaders. Default is 100.
Text height for dimensions before the overall scale is applied. Default is 2.5.